Volume 6, Issue 2 (Spring 2017)                   J Occup Health Epidemiol 2017, 6(2): 92-97 | Back to browse issues page


XML Print


1- Dept. of Environmental Health Engineering, School of Health, Occupational Environment Research Center, Rafsanjan University of Medical Sciences, Rafsanjan, Iran.
2- Dept. of Epidemiology and Biostatistics, Occupational Environmental Research Center, Medical School, Rafsanjan University of Medical Sciences, Rafsanjan, Iran.
3- Deputy of Health, Rafsanjan University of Medical Sciences, Rafsanjan, Iran.
4- School of Nursing and Midwifery, Rafsanjan University of Medical Sciences, Rafsanjan, Iran.
5- Dept. of Environmental Health Engineering, School of Health, Rafsanjan University of Medical Sciences, Rafsanjan, Iran. , mobinilk@gmail.com
Article history
Received: 2017/04/3
Accepted: 2017/06/18
ePublished: 2017/09/17
Abstract:   (6984 Views)
Background: Lighting is a basic need for human beings and affects their physical, physiological, and psychological behavior. The required level of lighting for visual performance must be provided in order to ensure health and wellbeing. Students spend much of their time studying in libraries, and thus, sufficient lighting is necessary in libraries. Therefore, the aim of the present study was to determine lighting intensity in university libraries in Rafsanjan, Iran.
Materials and Methods: The present cross-sectional study was conducted on 13 university libraries of Rafsanjan in April 2014. To assess natural and total lighting intensity, the network method was used. Lighting intensity was measured in a total of 314 stations in the university libraries of Rafsanjan. The collected data were analyzed using descriptive statistics.
Results: The men’s section of the library of Vali-E-Asr University of Rafsanjan had the highest total lighting intensity (1265.40 ± 530.95 lx) and the men's section of the library of the School of Medicine, Rafsanjan University of Medical Sciences, had the lowest total lighting intensity (91.06 ± 29.40 lx). Among the 13 study halls of the studied libraries, 4 (30.7%) halls had no windows. The lack of windows has an undesirable effect on the intensity of natural lighting.
Conclusions: Based on the results of this study, the average lighting intensity in 50% of the studied libraries was less than the Iranian standard. Therefore, the redesigning and modification of the lighting systems of these libraries are necessary.
Full-Text [PDF 352 kb]   (1418 Downloads) |   |   Full-Text (HTML)  (1399 Views)  

References
1. Bellia L, Bisegna F, Spad G. Lighting in indoor environments: visual and non-visual effects of light sources with different spectral power distributions. Build Environ 2011; 46(10):1984-92. [Article]
2. Hoffmann G, Gufler V, Griesmacher A, Bartenbach C, Canazeic M, Staggl S, et al. Effects of variable lighting intensities and colour temperatures on sulphatoxymelatonin and subjective mood in an experimental office workplace. Appl Ergon 2008; 39(6):719-28. [PubMed]
3. Juslén H, Tenner A. Mechanisms involved in enhancing human performance by changing the lighting in the industrial workplace. Int J Ind Ergon 2005; 35(9):843-55. [Article]
4. Van Bommel WJ. Non-visual biological effect of lighting and the practical meaning for lighting for work. Appl Ergon 2006; 37(4):461-6. [PubMed]
5. Stevens RG, Brainard GC, Blask DE, Lockley SW, Motta ME. Adverse health effects of nighttime lighting: comments on American Medical Association policy statement. Am J Prev Med 2013; 45(3):343-6. [PubMed]
6. Li Ch, Sun L, Hu X. A context-aware lighting control system for smart meeting rooms. Systems Engineering Procedia 2012; 4:314-23. [Article]
7. de Kort Y, Smolders K. Effects of dynamic lighting on office workers: first results of a field study with monthly alternating settings. Light Res Technol 2010; 42(3):345–360. [Article]
8. Scheer FA, Buijs RM. Light affects morning salivary cortisol in human. J Clin Endocrinol Metab 1999; 84(9):3395-8. [PubMed]
9. design_brief_library_lighting [Internet]. 2016 [Last accessed 2016 Sep] Avaiable from: http://www.lightingassociates.org/i/u/2127806/f/tech_sheets/design_brief_library_lighting.pdf
10. Rea MS. The IESNA lighting handbook: reference and application. 9th ed. NewYork, United States: Illuminating Engineering Society of North America; 2000. [Book]
11. Ghotbi Ravandi MR, Khanjani N, Nadri F, Nadri A, Nadri A, Ahmadian M, et al . Evaluation of illumination intensity and ultraviolet radiation at Kerman Medical University libraries. Iran Occupational Health 2012; 8(4):29-35. [Article]
12. Kalhor H. Illuminating engineering. 2nd ed. Tehran: Publishing Company; 2006. P.113-26.
13. Javan M, Barakat S, Dehghan H, Yosefi HA, Amiri M, Abram F. Evaluation of lighting intensity in dormitory study halls of Isfahan University of Medical Sciences, Iran. Journal of Health System Research 2013; 9(1):96-103.
14. Nadri H, Nikpey A, Nadri F, Rghalenavi M, Safari Varyani A, Avazpor M, et al . Measurement and design of general illumination in Qazvin Medical Science University student residences. Journal of Ilam University of Medical Science 2013; 20(5):59-66. [Article]
15. Maghsoodi Moghadam R, Farasati F, Toolabi A, Jafarzadeh Z. Light intensity and ultraviolet radiation in the libraries and computer sites of Ilam Universities. Journal of Health and Development 2014; 2(4):316-25. [Article]
16. Zamani M. The moment prediction global solar radiation in Rafsanjan city with neural network. Iranian Journal of Energy 2014; 16(4):15-32 [Article]
17. Winterbottom M, Wilkins AJ. Lighting and discomform in the classroom. J Environ Psychol 2009; 29: 63-75. [Article]
18. Kazemzadeh M, Tahbaz M. Measurement and analyzing daylight condition in traditional Kerman houses (Aminian house). Honar-Ha-Ye Ziba (Memari-Va-Shahrsazi) 2013; 18(2):17-26 [Article]
19. Espinoza LA, Monge-Nájera J. Lighting and noise level in the central facilities of the Costa Rican Distance Education University: health implications for staff and students. Cuadernos de Investigación UNED 2010; 2(1):63-8. [Article]
20. Zamanian Z, Barzideh M, Ghanbari S, Daneshmandi H. The survey of noise and light effects on body posture during the study in male dormitory of Shiraz University of Medical Sciences. Tolooe-E-Behdasht 2014; 13(4):48-56. [Article]
21. Madjidi F, Azimi Pirsaraei SR, Arghami SH. Measurement of the illumination in irregular geometric libraries of Zanjan city with Geospatial Information System (GIS). Journal of Zanjan University of Medical Sciences & Health Services 2009; 17(66):61-70. [Article]

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.